| •Digital
Pressure Sensor MPS-2/3 |
•Every pressure control zone is digitized
irrespective of pneumatic or hydraulic pressure.
•Easy to use
•NPN , PNP and Analog output (1-5V).
•There are three kinds of pressure cooking ranges, that
is, negative pressure, standard pressure, and compound pressure.
•Reliable CE mark.
•The current consumption is reduced thanks to energy saving
devices.
|
| |
TOP |
|
 |
| •Two color
expression Digital Pressure Sensor MPS-31 |
•The pressure change can be watched
by large-scale LED and two color luminescence.
•Two button method to pursue easiness to use
•There are abundant installation variations.
•The unit switch functions are attached. (For foreign countries):Negative,Positive,Compound
Preassure
•The current consumption is reduced thanks to energy saving
devices
•Reliable CE mark
|
| |
TOP |
|
 |
| •Digital
differential pressure sensor MPS-4 |
•Detection a slight pressure differential
with accurately.
•NPN Output, PNP Output and Analog output.
•Pressure control in two kinds of ranges for differential
Pressure)
|
| |
TOP |
|
 |
| •Separate
Type 1CH,4CH Digital Pressure Sensor MPS-5/6/8 |
•Pursuing total advantages of pressure
control
•The sensor heads are separated from indicators.
•Space-Saving (10mm width) (MPS8)
|
| |
TOP |
|
 |
| •Separate
Pressure Sensor Display MPS-71/74/78 |
•The total advantage of the pressure
management is pursued.
•It is possible to adjust and maintain machines where to
be seen easily.
•4 Cannels,8 Cannel expressions are cost advantageous.
•Equipped with energy saving function and limit watch function.
•Reliable CE mark.
|
| |
TOP |
|
 |
| •Vacuum
Sensor 10 mm width MPS-9 |
•Small-size, high-accuracy
•easy mode function.
•High-Seed response: less than 1.5 msec
•NPN-output,PNP-output ,Analog output(1-5V)
•Hysteresis operation and keylock function.
•DIN is available.
•Pressure Range: Negative,,Compound
•Reliable CE mark.
|
| |
TOP |
|
 |
| •Vacuum
Sensors MVS-030AB/035G |
•For munting on comvum
•MVS-035G with Analog Out put (1-5V)
|
| |
TOP |
|
|
•Digital Pressure Sensors with Solenoid Valves
Control MVS-201 |
 |
|
•Now changing from verification of pressure
to control of pressure.
•Integrated with Solenoid Valve Control can be mounted on
the CONVUM.
•Considerable reduction of air consumption is expected by
free setting of ultimate levels of vacuum.
•Loads on sequencers and other control can be reduced by
digital control of both negative and Positive pressure.
|
| |
TOP |
|
 |
| •Mechanical
Vacuum Switches CVA-V |
•Special-purpose switch for installation
on the CVA CONVUM
•The vacuum switch is designed to open and close the micro
switch through activation of the piston, and to verify that vacuum
reaches requested vacuum level
|
| |
TOP |
|
| |